CSA E926-98 pdf download

CSA E926-98 pdf download – Auxiliaries for lamps — Starting devices (other than glow starters) — General and safety requirements

CSA E926-98 pdf download – Auxiliaries for lamps — Starting devices (other than glow starters) — General and safety requirements.
1 Scope This standard specifies general and safety requirements for starting devices’ (starters and ignitors) for lubular fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 1 00 kV and which are used in combination with lamps and ballasts covered in IEC 81 , IEC 1 88, lEG 1 92, lEG 662, LEC 920 and IEC 922. NOTE — A standard on metal halide lamps is under consideration. This standard also covers starting devices for lamps which are not yet standardized. It does not apply 1 0 glow starters or starting devices which are incorporated in discharge lamps or which are manually operated. Preheal transformers for tubular fluorescent lamps are covered by IEC 920. Tests in this standard are type tests. Requirements for testing individual starting devices during production are not included. NOTE — Glow starters are included in IEC 1 55. 2 NormatIve references The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.
CE! 255-8: 1 990, Relais électriques — Huitiènie partie: Relais électriques the rmiques CE! 31 7-1 :1 990, Specifications pour types particuliers de fils de bobinage — Partie 1 : FL! de section circu/aire en cuivre émai/Ié avec acétal de polyvinyle, classe 1 05 CE! 41 0:1 973, Plans et regles d’échantillonnage pour les contróles par attributs CE! 41 7C: 1 977, Symboles graphiques ufilisabies sur le materiel — Index, relevé et compilation des feuilles individuelles Troisième complement CE! 529: 1 989, Degrés de protection procures par/es enveloppes (Code IP) CEI 598-1 : 1 992, Luminaires — Partie 1 : Prescriptions generales et essais CE! 662:1 980, Lampes a vapeurde sodium a haute pression CE! 695-2-1 : 1 991 , Essais re/atifs aux risques du feu — Partie 2: Méthodes d’essai — Section 1 : Essai au fil incandescent CE! 695-2-2: 1 991 , Essais relatifs aux risques du feu — Partie 2: Méthodes d’essai — Section 2: Essai au brOleur-aiguiJie CE! 81 7: 1 984, AppareL! d’essai de choc a ressort et son etalonnage CE! 920: 1 990, Ballasts pour lampes tubulaires a fluorescence — Prescriptions générales et prescriptions de sécurifé CE! 922: 1 989, Ballasts pour lampes a décharge (a I’exclusion des lampes tubulaires a fluorescence) — Prescriptions générales et prescriptions de sécurité CE! 927: 1 988, Dispositifs d’amorçage (autres que starters a lueur) — Prescriptions de performances CE! 990: Méthodes de mesure du courant de contact et du courant dans Ic conducteur de protection Iso 4046: 1 978, Papier, carton, pates et fermes connexes – Vocabulaire
3.3 amorceur: Disposilif d’amorçage destine a produire des impulsions de tension pour l’amorçage des lampes a decharge et qui n’assure pas le préchauffage des electrodes. NOTE — L’élément qui déclenche Pimputsion de tension d’amorçage peut étre soit a déclenchement synchro- nisé ou a déclenchement non synchronisé. 3.4 dispositlf d’amorçage a mise au repos automatique: Dispositif d’amorçage inter- disant les essais prolongésd’allumage des lampes qui ne s’allument pas, par exempie du fait de Ia désactivation des electrodes. NOTE — Dans le cas des starters, on entend par interruption des essais dallumage l’ouverture du circuit de préchauffage et/ou Ia limitation du courant de préchauttage a une valeur tout au plus égale au courant assigne de Ia lampe. Dans le cas des amorceurs, on entend par interruption des essais d’allumage I’arrét de Ia production d’impulsions de tension ou Ia reduction sensible de leur amplitude. 3.5 ballast: Appareil inséré entre l’alimentation et une ou plusieurs lampes a décharge et qul, a l’aide d’inductances et de capacités utilisées séparément ou en combinaison, a pour but principal d’ajuster le courant de (a ou des lampes a (a valeur requise. L’appareil peut comprendre un seul ou plusieurs éléments séparés. II peut egalement comporter des moyens de transformation de Ia tension d’alimentation et des dispositifs qui contribuent a foumir Ia tension d’amorcage et le courant de pré- chauff age, évitent ramorcage a froid, réduisent l’effet siroboscopique, corrigent le facteur de puissance et/ou diminuent les perturbations radioéleclriques. 3.6 tensIon d’allmentation: Tension appliquée au circuit dans lequel fonctionne le dispo- suit d’amorçage. 3.7 tension de service: Valeur efficace Ia plus élevée de (a tension qui s’applIque aux isolements, soit a circuit ouvert soit en lonctionnement avec une lampe, les phénomènes transitoires n’étanl pas pris en consideration, lorsque le dispositif d’amorçage fonctionne a sa tension assignee.CSA E926-98 pdf download.

Leave a Reply

Your email address will not be published. Required fields are marked *